These corrosion data are mainly based on results of general corrosion laboratory tests, carried out with pure chemicals and water solutions nearly saturated with air (the corrosion rate can be quite different if the solution is free from oxygen).

All concentrations are given in weight-% and the solvent is water if nothing else is shown. The corrosion data apply to annealed materials with normal microstructure and clean surfaces, throughout.

Phosphoric acid, H3PO4 + hydrofluoric acid, HF
Conc.H3PO4%1.541.441.441.441.441.441.441.441.4767676767676
Conc.HF%10.50.50.51112.52.50.50.50.50.511
Temp.°C5020406020406020-4060204060802040
Grade or type of alloy:
Carbon steel222222222222222
13 Cr222222222222222
Alleima® 1802212222222112212
Alleima® 3R12212222222112212
Alleima® 3R60201111212001100
18Cr13Ni3Mo 1)
201111111000100
17Cr14Ni4Mo 2)
100101111000100
Alleima® 2RK65 ('904L')100000101000100
Sanicro® 280010
254 SMO0111
654 SMO0010
SAF™ 23041221
SAF™ 220511p21
SAF™ 25070121
Titanium (CP Ti)211212222222222

1) ASTM 317L, e.g. Alleima® 3R64
2) EN 1.4439, e.g. Alleima® 3R68

Phosphoric acid, H3PO4 + hydrofluoric acid, HF
Conc. H3PO4 %7676767680
Conc. HF %1122.51
Temp. °C60802020120
Grade or type of alloy:
Carbon steel22222
13 Cr22222
Alleima® 180222222
Alleima® 3R1222222
Alleima® 3R6011012
18Cr13Ni3Mo 1)
11002
17Cr14Ni4Mo 2)
11002
Alleima® 2RK65 ('904L')01002
Sanicro® 2801
254 SMO12
654 SMO12
SAF™ 230422
SAF™ 220512
SAF™ 250712
Titanium (CP Ti)22222

1) ASTM 317L, e.g. Alleima® 3R64
2) EN 1.4439, e.g. Alleima® 3R68

Symbol clarification

These corrosion tables use a number of symbols, having the following meanings:

Symbol Description
0 Corrosion rate less than 0.1 mm/year. The material is corrosion proof.
1 Corrosion rate 0.1—1.0 mm/year. The material is not corrosion proof, but useful in certain cases.
2 Corrosion rate over 1.0 mm/year. Serious corrosion. The material is not usable.
p, P Risk (severe risk) of pitting and crevice corrosion.
c, C Risk (Severe risk) of crevice corrosion. Used when there is a risk of localised corrosion only if crevices are present. Under more severe conditions, when there is also a risk of pitting corrosion, the symbols p or P are used instead.
s, S Risk (Severe risk) of stress corrosion cracking.
ig Risk of intergranular corrosion.
BP Boiling solution.
ND No data. (Used only where there are no actual data to estimate the risk of localised corrosion instead of p or s).

Disclaimer: Laboratory tests are not strictly comparable with actual service conditions. Accordingly, Alleima makes no warranties, express or implied, and accept no liability, compensatory or consequential, for the performance of different materials in individual applications that may be based on the information provided in this publication.